Thermal Impacts of the Internal Courtyards in Compound Houses: The Case of Tamale Metropolis

Authors

  • Abdul Manan Dauda Email Tamale Technical University, Ghana

DOI:

https://doi.org/10.30564/jaeser.v4i4.3790
Received: 29 September 2021 | Published Online: 22 November 2021

Abstract

The research seeks to understand the effects of internal courtyards on
thermal comfort conditions in compound houses in Ghana’s Tamale
Metropolitan area. Internal courtyards are an integral part of the design of
compound houses in this location.
Their inclusion in building designs is largely as a point of domestic activity
such as cooking and cleaning and also for social interaction. However, a lot
of interchanges in thermal conditions between structures and the outdoors
take place within these internal courtyards. Various design details of the
building will engender different thermal responses of the internal courtyard.
This paper assesses thermal comfort in compound houses as against
bungalow type houses in the Tamale Metropolis, Ghana by the application
of the Predicted Percentage of Dissatisfied Persons (PPD) and Predicted
Mean Votes (PMV) model. This prototype compares with the International
Standards Organization (ISO) 7730 and American Society of Heating,
Refrigeration and Air-Conditioning Engineers (ASHRAE) Standard 55
(estimated values between 23˚C - 26˚C seen as the allowable temperatures).
Ambient indoor conditions (dry bulb temperature and relative humidity)
of five (5) buildings each from the two building typologies from were
recorded over a period of ten calendar months. These ambient conditions
were analyzed, consequently generating the Predicted Percentage of
Dissatisfied Persons (PPD) and Predicted Mean Votes (PMV) recordings.
The investigations uncovered relatively high PPD - PMV recordings
relating to the Bungalow type buildings while the compound houses
attune to the comfort zone. The Actual Mean Votes (AMV) of residents
suggests the two building typologies are all rated comfortable however; the
compound houses are rated above the bungalow type houses.

Keywords:

Compound house, Internal courtyard, Thermal comfort, ASHRAE criterion 55, Tamale metropolis

References

[1]Givoni, B., 1994. Passive and Low Energy Cooling of Buildings. 1st Edn, Van Nostrand Reinhold, New York, ISBN: 0471284734, pp: 4.

[2]Budaiwi, I.M., 2006. An approach to investigate and remedy thermal-comfort problems in buildings. Build. Environ, 42: 21 24-2131.

[3]Al-Hemiddi, N.A. and K.A. Megren Al-Saud, 2001. The effect of a ventilated interior courtyard on the thermal performance of a house in a hot-arid region. Renewable Energy, 24: 581-595.

[4]Muhaisen, A.S. and M.B. Gadi, 2006. Effect of courtyard proportions on solar heat gain and energy requirement in the temperate climate of Rome. Build. Environ. 41: 245-253.

[5]GSS. (2012). 2010 population and housing census: Summary report of final results. Accra: Ghana Statistical Service.

[6]Abankwa, V., Grimard, A., Sommer, K., & Kuria, F. (2009). Ghana: Tamale city profile. Nairobi: Regional Technical Cooperation Division, UN-Habitat.

[7]Ghana Meteorological Service, 2018.

[8]Ibrahim Yakubu*, Millicent Awialie Akaateba, Bernard A.A. Akanbang,(2014) A study of housing conditions and characteristics in the Tamale Metropolitan Area, Ghana, Habitat International Vol. 44 pp 394-402.

[9]Nicol, F.G. (2001) Characterising Occupant Behaviour in Buildings: Towards a Stochastic Model of Occupant Use of Windows, Lights, Blinds, Heaters and Fans. Proceedings of 7th International IBPSA Conference, Rio de Janeiro, 13-15 August 2001, 1073-1078.

[10]Brager, G.S. and De Dear, R.J. (1998) Thermal Adaptation in the Built Environment: A Literature Review. Energy and Buildings, 27, 83-96.

[11]Oseland, N.A. (1995) Predicted and Reported Thermal Sensation in Climate Chambers, Offices and Homes. Energy and Buildings, 23, 105-115. DOI: http://dx.doi.org/10.1016/0378-7788(95)00934-5.

[12]American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE) (2004) Standard 55-2004 & Standard 55-1992, Thermal Environmental Conditions for Human Occupancy. ASHRAE, Atlanta.

[13]ISO 7730 (2005) Moderate Thermal Environments Determination of the PMV and PPD Indices and Specifications for Thermal Comfort. 2nd Edition, International Organization for Standardization, Geneva.

[14]Szokolay, S. (2004) Introduction to Architectural Science: The Basis of Sustainable Design. Architectural Press, Oxford, 17.

[15]Hyde, R. and Sabarinah, S.A. (2008) Bioclimatic Housing, Innovative Designs for Warm Climates. Earthscan, UK & USA.

[16]Humphreys, M.A. and Nicol, J.F. (2002) The Validity of ISO-PMV for Predicting Comfort Votes in Everyday Thermal Environments. Energy and Buildings, 34, 667-684. DOI: http://dx.doi.org/10.1016/S0378-7788(02)00018-X.

[17]Fanger, P.O. (1970) Thermal Comfort. Danish Technical Press. Copenhagen.

[18]de Dear, R.J. and Brager, G.S. (2002) Thermal Comfort in Naturally Ventilated Buildings: Revision to ASHRAE Standard 55. Energy and Buildings, 34, 549-561. DOI: http://dx.doi.org/10.1016/S0378-7788(02)00005-1

[19]Beizaee, A., Firth, S.K., Vadodaria, K. and Loveday, D. (2012) Assessing the Ability of PMV Model in Predicting Thermal Sensation in Naturally Ventilated Buildings in UK. 7th Windsor Conference: The Changing Context of Comfort in an Unpredictable World, Windsor, 12-15 April 2012, Network for Comfort and Energy Use in Buildings, London. http://nceub.org.uk.

[20]Han, J., Zhang, G., Zhang, Q., Zhang, J., Liu, J., Tian, L., Zheng, C., Hao, J., Lin, J., Liu, Y. and Moschandreas, D.J. (2007) Field study on Occupants’ Thermal Comfort and Residential Thermal Environment in a Hot-Humid Climate of China. Building and Environment, 42, 4043-4050. DOI: http://dx.doi.org/10.1016/j.buildenv.2006.06.028.

[21]Heidari, S. and Sharples, S. (2002) A Comparative Analysis of Short-Term and Long-Term Thermal Comfort Surveys in Iran. Energy and Buildings, 34, 607-614. DOI: http://dx.doi.org/10.1016/S0378-7788(02)00011-7.

[22]Barbara Simons, Christian Koranteng, Emmanuel Adinyira and Joshua Ayarkwa, (2014) An Assessment of Thermal Comfort in Multi Storey Office Buildings in Ghana, Journal of Building Construction and Planning Research, 2014, 2, 30-38.

[23]Koranteng, C. and Abaitey, E.G. (2010) The Effects of Form and Orientation on Energy Performance of Residential Buildings in Ghana, Journal of Science and Technology, 30, 71-81.

[24]Koranteng, C. and Mahdavi, A. (2010) An Enquiry into the Thermal Performance of Five Office Buildings in Ghana. 10th Revha World Congress on Sustainable Energy Use in Buildings (CLIMA 2010), Antalya, 9-12 May 2010.

[25]Doherty, T.J. and Arens, E. (1988) Evaluation of the Physiological Bases of Thermal Comfort Models. ASHRAE Transactions, 94, 1371-1385.

[26] Morgan, C.A., De Dear, R. and Brager, G. (2002) Climate, Clothing and Adaptation in the Built Environment. In: Levin, H., Ed., Indoor Air 2002: The 9th International Conference on Indoor Air Quality and Climate, Monterey, 30 June-5 July 2002, 98-103.

Downloads

Issue

Article Type

Article